Which glucose number are you looking at?
- Number
- Estimated average glucose (eAG)
- What it uses
- The laboratory A1C and an equation derived from a group of study participants.
- Time it represents
- About three months. Recent weeks have more influence on A1C.See reference 1,See reference 2
- Number
- Meter or lab glucose reading
- What it uses
- Glucose measured from a sample at a particular time.
- Time it represents
- The time of that measurement. Meals and activity can affect the result.See reference 1,See reference 2
- Number
- Sensor average (CGM)
- What it uses
- Glucose readings collected by a continuous glucose monitor.
- Time it represents
- The dates and readings covered by the sensor report. A shorter report can reflect more recent changes.See reference 1,See reference 2
How the report gets the eAG number
The A1C-Derived Average Glucose study compared lab A1C with three months of sensor and fingerstick readings in 507 participants. Its equation for mg/dL is 28.7 × A1C (%) − 46.7. The equation takes the percentage as shown, so an A1C of 6.0% enters as 6.0. An A1C reported in mmol/mol is on a different scale and cannot be entered directly.See reference 1,See reference 3
For an example A1C of 6.0%, 28.7 × 6.0 − 46.7 gives 125.5 mg/dL, about 126 mg/dL. The study’s mmol/L equation gives 1.59 × 6.0 − 2.59 = 6.95 mmol/L, about 7.0 mmol/L. These figures describe one hypothetical lab report and supply no individual target.See reference 1,See reference 3
Why your eAG and sensor average can differ
Start by checking the units and the date range on the sensor or meter report. A device average reflects the readings it captured. An eAG uses the relationship observed across study participants, and people with the same A1C can have different measured averages. One average also hides highs, lows and the timing of changes.See reference 1,See reference 2
Anything that makes an A1C result unreliable can affect its eAG too. Recent blood loss or transfusion can change the red blood cells being measured. Some hemoglobin variants affect certain lab methods. Bring the A1C result, the device report and relevant testing history to your care team if the discrepancy persists.See reference 1,See reference 2
Common questions
Do A1C and eAG measure two different things?
The lab measures A1C and uses that value to calculate eAG. Both numbers come from the same A1C result.See reference 1,See reference 2
Can eAG tell me what my glucose is right now?
A current glucose reading supplies information about that moment. The estimated average reflects the longer period represented by A1C.See reference 1,See reference 2
Do I need to fast for an eAG on my A1C report?
The A1C blood draw itself does not require fasting. If other tests are on the same order, follow the laboratory’s instructions for those tests.See reference 2
Compare results in the same glucose units
If you already have a glucose value in mg/dL or mmol/L, convert that value to the other unit.
Open glucose unit converterGet the weekly longevity brief
The week's best longevity research in plain English. Free, every Tuesday.
References
- 1. Translating the A1C Assay Into Estimated Average Glucose Values
Nathan and colleagues, Diabetes CareObservational study
- 2. The A1C Test & Diabetes
National Institute of Diabetes and Digestive and Kidney DiseasesOfficial guidance
- 3. HbA1c and Estimated Average Glucose
National Glycohemoglobin Standardization ProgramOfficial guidance
Editorial transparency
- Published by
- LongevityMate Editorial
- Reviewed by
- Editorial evidence review (AI-assisted)
- Published
- Updated
Medical disclaimer
For general education. A qualified health professional can interpret your results and advise on testing, medicines or supplements.